When school guarding is replaced, the glass question usually comes first: toughened or laminated, and how thick? The useful answer depends on more than the glass. How the panels are held, the gaps around them and whatever else forms part of the guarding all shape the right specification. A recent Balconette replacement at Greasley Beauvale School in Nottinghamshire shows how one specification was reached, and why.
What was there before
The existing guarding used 10 mm glass panels held on lugs: individual point fixings rather than continuous support along the panel. That arrangement left large gaps at the sides of the panels. A steel mesh sat underneath the glass.
What the replacement changed
The request from the architects was to create a tall non climbable solution with no (or minimal) gaps for fingers. The request was that it also needed to retain the existing posts which were already inserted into the wall construction.
Our system moved the glass line forward by around 50-60 mm and it replaced the lug-held arrangement which removed the large gaps at the sides of the panels. The steel mesh was kept behind the glass, and a special handrail which allows the glass to pass through it was designed. This gave a strong element at the point of the horizontal line load and allowed the glass to span to 1800 mm tall to complete the arrangement.
Each part has a role:
- the glass gives a smooth face with no side openings and no footholds;
- the existing steel mesh was retained behind the replacement glass as an additional barrier but also because it supported the decking boards that connected to the floor;
- the handrail gave a visible sightline and a point to secure the tall glass, without also being something that could be stood upon.
This is why the glass decision can’t be made in isolation.
Why 10 mm toughened glass
The architects selected 10 mm toughened glass from the available options. Two practical reasons drove it:
- the existing glass in the previous system was 10 mm, so the replacement matched what the installation was designed around;
- weight mattered. Glass weighs about 25 kg per square metre for every 10 mm of thickness, at 1.8 m tall that’s 45 kg per linear metre, so every step up adds load to the existing structure and makes the panels harder to handle and install.
Toughened glass is around four to five times stronger for impact than ordinary annealed glass of the same thickness. 10 mm glass is known as “safety glass” because if it does break it shatters into small fragments rather than large sharp and dangerous shards. Its limitation is that a broken monolithic toughened panel does not stay in place.
The design of the system we supplied allows for the handrail to remain in place and be able to support the load should a panel break. In addition to this the existing steel mesh at Greasley Beauvale was retained behind the glass as an additional barrier.

What would the laminated alternative have looked like?
The interlayer in laminated glass helps retain fragments after breakage. Where one pane remains intact, it can also help support the damaged panel.
The laminated alternative we considered for this project was 21.5 mm thick, comprising two 10 mm toughened glass plies bonded with a PVB interlayer. This would potentially add fragment retention after breakage, but would roughly double the glass weight compared with the selected 10 mm toughened panels which was already putting weight at the limit on the existing floor location.
That roughly doubles the glass weight, to about 50 kg per square metre (or 90 kg in this case due to the height), and needs supports and fixings sized for the thicker, heavier panel. Stiffer structural interlayers, such as SentryGlas®, help a broken laminated panel hold its shape better than a standard PVB interlayer, but add further cost.
Where there is nothing behind the glass, that post-breakage performance can be the deciding factor. As 10 mm toughened glass was already in use on this project, we considered a 21.5 mm laminated alternative but ruled it out because of the additional weight and cost. The architects and structural engineers ultimately approved the 10 mm clear toughened panels and retained the existing steel mesh behind the glass as an additional barrier.
Gaps, fixings and climbability
For primary-age children, the details around the glass matter as much as the glass itself: guarding height, smooth internal faces, the size of any gaps, and fixings or rails that could become footholds. Removing the lug fixings and the side gaps addressed the two weakest points of the original installation. Our article on non-climbable balustrades in primary schools covers these in more detail, with photographs and a walkaround video of a school installation.
Replacing glass guarding at your school?
Send us:
- photographs of the existing installation, including close-ups of the fixings and any gaps;
- approximate dimensions (panel sizes, heights and overall runs);
- existing drawings, if you have them;
- what you want to improve.
We can then propose a replacement arrangement, with glass options and their implications for weight and support, for your design team to consider. Call 01342 410411 or email enquiries@balconette.co.uk.